Industrial Controllers and RTUs

6 Products

Red Lion - ST-IPM-6350 - Industrial Controllers & RTUs

Red Lion - Performance Specifications Industrial PowerPC (32 bit data bus) Operating system: embedded LINUX Dynamic memory (RAM): 16+ Megabytes - 32bit; 0 wait states Program memory (Flash): 16+ Megabytes Datalogging memory NVRAM: 2 MB (battery-backed) Maximum local I/O: 640 Datalogging support: Sixnet Sixlog IEC 61131 programming: Sixnet ISaGRAF High Level C programming: LINUX open software Ethernet Ports (All) 10/100BaseTx (auto-detecting) Connection: RJ45 (auto-crossover) Protocols: TCP/IP, ARP, UDP, ICMP, DHCP, Modbus/TCP, Sixnet and more Independent networks: 2 w/ unique MAC and IP addresses Network port 1: (1) shielded RJ45 connector Network port 2: (4) shielded RJ45 connectors (linked via integrated industrial Ethernet switch) Serial Port Up to 115,200 baud RS-232 Port A RJ45 (TD, RD, CTS, RTS, CD,TR, DSR, GND) RS-232 Port B RJ45 (TD, RD, CTS, RTS, CD, DTR, DSR, GND) RS-485 Port C Screws (485+, 485-, GND) (2-wire half-duplex) Protocols (master or slave): Sixnet and Modbus RTU/ASCII; many others available in LINUX Flow control - hardware, software, half/full-duplex modem Environmental DIN-rail or flat-panel mount Input power: 10-30 VDC Input current: 150 mA @ 24 VDC (typical) Temperature: -40 to 70°C (-40 to 85°C storage) Humidity: 5% to 95% RH (non-condensing) Flammability: UL 94V-0 materials Electrical Safety: UL 508, CSA C22.2/14; EN61010-1 (IEC1010); CE EMI emissions: FCC part 15, ICES-003, Class A; EN55022; EN61326-1; CE EMC immunity: EN61326-1 (EN61000-4-2,3,4,6); CE Vibration: IEC68-2-6 Hazardous locations: UL 1604, CSA C22.2/213, (Class 1, Div 2, Groups A,B,C,D) Cenelec EN50021 Zone 2 MTBF ST-IPm-6350: 2,003,287 Hours GB @ 40°C per MIL-HNDBK-217F2 Marine/offshore tested and/or verified to meet various marine and maritime standards
$2,341.00

Red Lion - VT-IPM2M-113-D - Industrial Controllers & RTUs

Red Lion - Performance Specifications Industrial PowerPC (32 bit data bus) Operating system embedded open-source Linux Dynamic memory (RAM) 32 Mb for program execution, dynamic variables, dynamic file system, etc. Program memory (Flash) 32 Mb for Linux OS, program storage and file system Retained memory (RAM) 512K (battery-backed) for datalogging and retained variables Real-time clock battery-backed for time stamping and other operations I/O Expansion RS-485 or Ethernet Datalogging support IEC 61131 programming, ISaGRAF for ladder logic, SFC, flow charting and more (6 languages supported) High Level C programming Ethernet Port 10/100BaseTx (auto-detecting) RJ45 connection (auto-crossover) Protocols TCP / IP, ARP, UDP, ICMP, DHCP, Modbus / TCP, Sixnet, optionally PPP, DNP3, IEC60870-5-101/104 and more Serial Port Up to 115,200 baud RS-485 Port A screws (485+, 485-, GND) (2-wire half-duplex) RS-232 Port B RJ45 (TD, RD, CTS, RTS, CD, DTR, DSR, GND) Protocols Master and slave modes; Sixnet and Modbus RTU / ASCII; optional: Slave; DNP3, IEC60870-5-101/104. Others available as Linux applications Discrete Inputs 12 channels sourcing or sinking (jumper/software selectable) Guaranteed ON voltage 9 VDC Maximum voltage 30 VDC Guaranteed OFF voltage 5.0 VDC and 1.5 mA DC Input resistance and current 10K Ohms and 3 mA @ 24 VDC Filtered ON/OFF delay 25 mS (20 Hz max. counting) for contact bounce filtering Fast ON/OFF delay 4 mS (100 Hz max. counting) Count rate (see above) (10 KHz on channel 1 only) Counter modes pulse, rate and run time Poll time (all channels) 5 mS to 20 mS configuration dependent Discrete Outputs 4 channels – sourcing 10-30 VDC Min. and max. output load 1 mA to 1 Amp sourcing per channel Max. OFF state leakage 0.05 mA Inrush current 5 Amps (100 mS surge) Typical ON characteristics 0.3 Ohms resistance and 0.3 VDC voltage drop @ 1A Poll time (all channels) 5 mS to 20 mS configuration dependent Analog Inputs 8 channels – current or voltage selectable Full scale range 4-20 mA or 0-5 VDC (jumper selectable) A/D and input resolution 16 bits (0.003%); 2 uA (current range) or 0.5 mV (voltage range) Full scale accuracy +/-0.1% (@20°C) (factory calibration) Span and offset temp. coeff. +/-50 ppm per °C Input impedance 100 Ohm (current range), 80 K Ohm voltage Current protection Self-resetting fuses (for 4-20 mA range) DMRR 66 dB at 50/60 Hz (differential mode rejection) CMRR (common mode rejection) Not applicable since analog inputs are single ended. Fastest update time 50 mS (both channels) – configurable for longer integration times for better noise filtering Environmental DIN-rail or panel-mount Input power 10-30 VDC Input current 100 mA @ 24 VDC (typical) Temperature -40 to 70°C (-40 to 85°C storage) Humidity 5% to 95% RH (non-condensing) Flammability UL 94V-0 materials Electrical safety UL 508, CSA C22.2/14; EN610101; (IEC1010) EMI emissions FCC part 15, ICES-003, Class A; EN55022; EN61326-1 EMC immunity EN61326-1 (EN61000-4-2,3,4,6) Surge withstand IEEE-472 (ANSI C37.90) Vibration IEC68-2-6 Hazardous locations (Class 1, Div 2, Groups A,B,C,D) UL 1604, CSA C22.2/213, Cenelec EN50021 Zone 2 Tested to Marine/offshore standards
$1,083.00

Red Lion - VT-IPM2M-213-D - Industrial Controllers & RTUs

Red Lion - Industrial PowerPC (32 bit data bus) Operating system embedded open-source Linux Dynamic memory (RAM) 32 Mb for program execution, dynamic variables, dynamic file system, etc. Program memory (Flash) 32 Mb for Linux OS, program storage and file system Retained memory (RAM) 512K (battery-backed) for datalogging and retained variables Real-time clock battery-backed for time stamping and other operations I/O Expansion RS-485 or Ethernet Datalogging support IEC 61131 programming, ISaGRAF for ladder logic, SFC, flow charting and more (6 languages supported) High Level C programming Ethernet Port 10/100BaseTx (auto-detecting) RJ45 connection (auto-crossover) Protocols TCP / IP, ARP, UDP, ICMP, DHCP, Modbus / TCP, Sixnet, optionally PPP, DNP3, IEC60870-5-101/104 and more Serial Port Up to 115,200 baud RS-485 Port A screws (485+, 485-, GND) (2-wire half-duplex) RS-232 Port B RJ45 (TD, RD, CTS, RTS, CD, DTR, DSR, GND) Protocols Master and slave modes; Sixnet and Modbus RTU / ASCII; optional: Slave; DNP3, IEC60870-5-101/104. Others available as Linux applications Discrete Inputs 12 channels sourcing or sinking (jumper/software selectable) Guaranteed ON voltage 9 VDC Maximum voltage 30 VDC Guaranteed OFF voltage 5.0 VDC and 1.5 mA DC Input resistance and current 10K Ohms and 3 mA @ 24 VDC Filtered ON/OFF delay 25 mS (20 Hz max. counting) for contact bounce filtering Fast ON/OFF delay 4 mS (100 Hz max. counting) Count rate (see above) (10 KHz on channel 1 only) Counter modes pulse, rate and run time Poll time (all channels) 5 mS to 20 mS configuration dependent Discrete Outputs 4 channels – sourcing 10-30 VDC Min. and max. output load 1 mA to 1 Amp sourcing per channel Max. OFF state leakage 0.05 mA Inrush current 5 Amps (100 mS surge) Typical ON characteristics 0.3 Ohms resistance and 0.3 VDC voltage drop @ 1A Poll time (all channels) 5 mS to 20 mS configuration dependent Analog Inputs 8 channels – current or voltage selectable Full scale range 4-20 mA or 0-5 VDC (jumper selectable) A/D and input resolution 16 bits (0.003%); 2 uA (current range) or 0.5 mV (voltage range) Full scale accuracy +/-0.1% (@20°C) (factory calibration) Span and offset temp. coeff. +/-50 ppm per °C Input impedance 100 Ohm (current range), 80 K Ohm voltage Current protection Self-resetting fuses (for 4-20 mA range) DMRR 66 dB at 50/60 Hz (differential mode rejection) CMRR (common mode rejection) Not applicable since analog inputs are single ended. Fastest update time 50 mS (both channels) – configurable for longer integration times for better noise filtering Analog Outputs 2 channels (4-20 mA) D/A resolution 16 bits (less than 1µA) Full scale accuracy (@20°C) +/- 0.02% Span and offset temp. coef. +/- 50 ppm per °C typical Max. output settling time 5 mS (to .05%) Load resistance range (@ +24 VDC supply) 0-750 Ohms Short circuit protection current limiting Environmental DIN-rail or panel-mount Input power 10-30 VDC Input current 100 mA @ 24 VDC (typical) Temperature -40 to 70°C (-40 to 85°C storage) Humidity 5% to 95% RH (non-condensing) Flammability UL 94V-0 materials Electrical safety UL 508, CSA C22.2/14; EN610101; (IEC1010) EMI emissions FCC part 15, ICES-003, Class A; EN55022; EN61326-1 EMC immunity EN61326-1 (EN61000-4-2,3,4,6) Surge withstand IEEE-472 (ANSI C37.90) Vibration IEC68-2-6 Hazardous locations (Class 1, Div 2, Groups A,B,C,D) UL 1604, CSA C22.2/213, Cenelec EN50021 Zone 2 Tested to Marine/offshore standards
$1,264.00

Red Lion - VT-MIPM-135-D - Industrial Controllers & RTUs

Red Lion - Performance Specifications Industrial PowerPC (32 bit data bus) Operating system embedded open-source Linux Dynamic memory (RAM) 32 Mb for program execution, dynamic variables, dynamic file system, etc. Program memory (Flash) 64 Mb for Linux OS, program storage and file system Retained memory (RAM) 512K (battery-backed) for datalogging and retained variables Real-time clock battery-backed for time stamping and other operations I/O Expansion RS-485 or Ethernet Datalogging support IEC 61131 programming, ISaGRAF for ladder logic, SFC, flow charting and more (6 languages supported) High Level C programming Ethernet Port 10/100BaseTx (auto-detecting) RJ45 connection (auto-crossover) Protocols TCP / IP, ARP, UDP, ICMP, DHCP, Modbus / TCP, Sixnet, optionally PPP, DNP3, IEC60870-5-101/104 and more Serial Port Up to 115,200 baud RS-485 Port A screws (485+, 485-, GND) (2-wire half-duplex) RS-232 Port B RJ45 (TD, RD, CTS, RTS, CD, DTR, DSR, GND) RS-232 Port D Screws (TD, RD, GND) Protocols Master and slave modes; Sixnet and Modbus RTU / ASCII; optional: Slave; DNP3, IEC60870-5-101/104. Others available as Linux applications Discrete Inputs 12 channels sourcing or sinking (jumper/software selectable) Guaranteed ON voltage 9 VDC Maximum voltage 30 VDC Guaranteed OFF voltage 5.0 VDC and 1.5 mA DC Input resistance and current 10K Ohms and 3 mA @ 24 VDC Filtered ON/OFF delay 25 mS (20 Hz max. counting) for contact bounce filtering Fast ON/OFF delay 4 mS (100 Hz max. counting) Count rate (see above) (10 KHz on channel 1 only) Counter modes pulse, rate and run time Poll time (all channels) 5 mS to 20 mS configuration dependent Discrete Outputs 8 channels Min. and max. output load 1 mA to 1 Amp sourcing per channel Max. OFF state leakage 0.05 mA Inrush current 5 Amps (100 mS surge) Typical ON characteristics 0.3 Ohms resistance and 0.3 VDC voltage drop @ 1A Poll time (all channels) 5 mS to 20 mS configuration dependent Analog Inputs 6 channels Full scale range 4-20 mA A/D and input resolution 16 bits (0.003%); 2 uA (current range) Full scale accuracy +/-0.1% (@20°C) (factory calibration) Span and offset temp. coeff. +/-50 ppm per °C Input impedance 100 Ohm (current range), 80 K Ohm voltage Current protection Self-resetting fuses DMRR 66 dB at 50/60 Hz (differential mode rejection) CMRR (common mode rejection) Not applicable since analog inputs are single ended. Fastest update time 50 mS (both channels) – configurable for longer integration times for better noise filtering Environmental DIN-rail or panel-mount Input power 10-30 VDC Input current 100 mA @ 24 VDC (typical) Temperature -40 to 70°C (-40 to 85°C storage) Humidity 5% to 95% RH (non-condensing) Flammability UL 94V-0 materials Electrical safety UL 508, CSA C22.2/14; EN610101; (IEC1010) EMI emissions FCC part 15, ICES-003, Class A; EN55022; EN61326-1 EMC immunity EN61326-1 (EN61000-4-2,3,4,6) Surge withstand IEEE-472 (ANSI C37.90) Vibration IEC68-2-6 Hazardous locations (Class 1, Div 2, Groups A,B,C,D) UL 1604, CSA C22.2/213, Cenelec EN50021 Zone 2 Tested to Marine/offshore standards
$1,812.00

Red Lion - VT-MIPM-245-D - Industrial Controllers & RTUs

Red Lion - Industrial PowerPC (32 bit data bus) Operating system embedded open-source Linux Dynamic memory (RAM) 32 Mb for program execution, dynamic variables, dynamic file system, etc. Program memory (Flash) 64 Mb for Linux OS, program storage and file system Retained memory (RAM) 512K (battery-backed) for datalogging and retained variables Real-time clock battery-backed for time stamping and other operations I/O Expansion RS-485 or Ethernet Datalogging support IEC 61131 programming, ISaGRAF for ladder logic, SFC, flow charting and more (6 languages supported) High Level C programming Ethernet Port 10/100BaseTx (auto-detecting) RJ45 connection (auto-crossover) Protocols TCP / IP, ARP, UDP, ICMP, DHCP, Modbus / TCP, Sixnet, optionally PPP, DNP3, IEC60870-5-101/104 and more Serial Port Up to 115,200 baud RS-485 Port A screws (485+, 485-, GND) (2-wire half-duplex) RS-232 Port B RJ45 (TD, RD, CTS, RTS, CD, DTR, DSR, GND) RS-485 Port C (GND, 485+, 485-, T) RS-232 Port D Screws (TD, RD, GND) Protocols Master and slave modes; Sixnet and Modbus RTU / ASCII; optional: Slave; DNP3, IEC60870-5-101/104. Others available as Linux applications Discrete Inputs 12 channels sourcing or sinking (jumper/software selectable) Guaranteed ON voltage 9 VDC Maximum voltage 30 VDC Guaranteed OFF voltage 5.0 VDC and 1.5 mA DC Input resistance and current 10K Ohms and 3 mA @ 24 VDC Filtered ON/OFF delay 25 mS (20 Hz max. counting) for contact bounce filtering Fast ON/OFF delay 4 mS (100 Hz max. counting) Count rate (see above) (10 KHz on channel 1 only) Counter modes pulse, rate and run time Poll time (all channels) 5 mS to 20 mS configuration dependent Discrete Outputs 4 channels – sourcing 10-30 VDC Min. and max. output load 1 mA to 1 Amp sourcing per channel Max. OFF state leakage 0.05 mA Inrush current 5 Amps (100 mS surge) Typical ON characteristics 0.3 Ohms resistance and 0.3 VDC voltage drop @ 1A Poll time (all channels) 5 mS to 20 mS configuration dependent Analog Inputs 8 channels – current or voltage selectable Full scale range 4-20 mA or 0-5 VDC (jumper selectable) A/D and input resolution 16 bits (0.003%); 2 uA (current range) or 0.5 mV (voltage range) Full scale accuracy +/-0.1% (@20°C) (factory calibration) Span and offset temp. coeff. +/-50 ppm per °C Input impedance 100 Ohm (current range), 80 K Ohm voltage Current protection Self-resetting fuses (for 4-20 mA range) DMRR 66 dB at 50/60 Hz (differential mode rejection) CMRR (common mode rejection) Not applicable since analog inputs are single ended. Fastest update time 50 mS (both channels) – configurable for longer integration times for better noise filtering ?Analog Outputs 2 channels (4-20 mA) A/D resolution 16 bits (0.003%) Full scale accuracy +/-0.1% (@20°C) Span and offset temp. coef. +/-50 ppm per °C Input impedance 100 Ohm Current protection Self-resetting fuses DMRR (differential mode rejection) 66 dB at 50/60 Hz Environmental DIN-rail or panel-mount Input power 10-30 VDC Input current 100 mA @ 24 VDC (typical) Temperature -40 to 70°C (-40 to 85°C storage) Humidity 5% to 95% RH (non-condensing) Flammability UL 94V-0 materials Electrical safety UL 508, CSA C22.2/14; EN610101; (IEC1010) EMI emissions FCC part 15, ICES-003, Class A; EN55022; EN61326-1 EMC immunity EN61326-1 (EN61000-4-2,3,4,6) Surge withstand IEEE-472 (ANSI C37.90) Vibration IEC68-2-6 Hazardous locations (Class 1, Div 2, Groups A,B,C,D) UL 1604, CSA C22.2/213, Cenelec EN50021 Zone 2 Tested to Marine/offshore standards
$2,054.00

Red Lion - VT-UIPM-431-H - Industrial Controllers & RTUs

Red Lion - Performance Specifications Industrial PowerPC (32 bit data bus) Operating system embedded open-source Linux Dynamic memory (RAM) 16 Mb for program execution, dynamic variables, dynamic file system, etc. Program memory (Flash) 16 Mb for Linux OS, program storage and file system Retained memory (RAM) 512K (battery-backed) for datalogging and retained variables Real-time clock battery-backed for time stamping and other operations I/O Expansion (up to 256) RS-485 or Ethernet Datalogging support IEC 61131 programming, ISaGRAF for ladder logic, SFC, flow charting and more (6 languages supported) High Level C programming Ethernet Port 10/100BaseTx (auto-detecting) RJ45 connection (auto-crossover) Protocols TCP / IP, ARP, UDP, ICMP, DHCP, Modbus / TCP, Sixnet, optionally PPP, DNP3, IEC60870-5-101/104 and more Serial Port Up to 115,200 baud RS-485 Port A screws (485+, 485-, GND) (2-wire half-duplex) RS-232 Port B RJ45 (TD, RD, CTS, RTS, CD, DTR, DSR, GND) RS-232 Port C Screws (TD, RD, RTS, GND) Protocols Master and slave modes; Sixnet and Modbus RTU / ASCII; optional: Slave; DNP3, IEC60870-5-101/104. Others available as Linux applications Discrete Inputs 8 channels sourcing or sinking (jumper/software selectable) Guaranteed ON voltage 9 VDC Maximum voltage 30 VDC Guaranteed OFF voltage 5.0 VDC and 1.5 mA DC Input resistance and current 10K Ohms and 3 mA @ 24 VDC Filtered ON/OFF delay 25 mS (20 Hz max. counting) for contact bounce filtering Fast ON/OFF delay 4 mS (100 Hz max. counting) Count rate (see above) (10 KHz on channel 1 only) Counter modes pulse, rate and run time Poll time (all channels) 5 mS to 20 mS configuration dependent Discrete Outputs 4 channels – sourcing 10-30 VDC Min. and max. output load 1 mA to 1 Amp sourcing per channel Max. OFF state leakage 0.05 mA Inrush current 5 Amps (100 mS surge) Typical ON characteristics 0.3 Ohms resistance and 0.3 VDC voltage drop @ 1A Poll time (all channels) 5 mS to 20 mS configuration dependent Analog Inputs 2 channels Full scale range 4-20 A/D and input resolution 16 bits (0.003%); 2 uA (current range) Full scale accuracy +/-0.1% (@20°C) (factory calibration) Span and offset temp. coeff. +/-50 ppm per °C Input impedance 100 Ohm (current range), 80 K Ohm voltage Current protection Self-resetting fuses DMRR 66 dB at 50/60 Hz (differential mode rejection) CMRR (common mode rejection) Not applicable since analog inputs are single ended. Fastest update time 50 mS (both channels) – configurable for longer integration times for better noise filtering Environmental DIN-rail or panel-mount Input power 10-30 VDC Input current 100 mA @ 24 VDC (typical) Temperature -40 to 70°C (-40 to 85°C storage) Humidity 5% to 95% RH (non-condensing) Flammability UL 94V-0 materials Electrical safety UL 508, CSA C22.2/14; EN610101; (IEC1010) EMI emissions FCC part 15, ICES-003, Class A; EN55022; EN61326-1 EMC immunity EN61326-1 (EN61000-4-2,3,4,6) Surge withstand IEEE-472 (ANSI C37.90) Vibration IEC68-2-6 Hazardous locations (Class 1, Div 2, Groups A,B,C,D) UL 1604, CSA C22.2/213, Cenelec EN50021 Zone 2 Tested to Marine/offshore standards
$900.00

Technical ResourcesVideosSoftware